ÉîÛÚÊÐÌìÎ¬ÔÆÍøÂç¿Æ¼¼ÃëËÙÈü³µÎªÄúÃâ·ÑÌṩȺêÍNAS¡¢ÆÕ°²´æ´¢¡¢³¬ÈÚºÏÒ»Ìå»úµÈÏà¹ØÐÅÏ¢·¢²¼ºÍ×îÐÂ×ÊѶ£¬¾´Çë¹Ø×¢£¡

ȺêÍNAS_infortrend_ÉîÛÚ´÷¶û´úÀíÉÌ-ÉîÛÚÊÐÌìÎ¬ÔÆÍøÂç¿Æ¼¼ÃëËÙÈü³µ

ÉîÛÚÊÐÌìÎ¬ÔÆÍøÂç¿Æ¼¼ÃëËÙÈü³µ

ÏúÊÛÈÈÏߣº13798559654

·þÎñÈÈÏߣº0755-82577366

ÁªÏµÌìÎ¬ÔÆ

0755-82577366

ÊÖ»ú£º13798559654

´«Õ棺0755-82577399

ÓÊÏ䣺service@sztwy.com

µØÖ·£º¹ã¶«Ê¡ÉîÛÚÊи£ÌïÇø»ªÇ¿±±Â·Èü¸ñ¿Æ¼¼Ô°Èý¶°¶«×ù

Dell EMC SCv3000

¾­¼Ãʵ»ÝµÄ»ìºÏÕóÁС£SCϵÁÐ×Ô¶¯·Ö²ãºÍÆóÒµ¼¶´æ´¢¹¦ÄܵÄÈ«ÐÂÈëÃż¶²úÆ·
È«¹ú·þÎñÈÈÏߣº0755-82577366
Á¢¼´×Éѯ

¼¼Êõ¹æ¸ñ

»úÏä¸ÅÀÀ

»úÏäÀàÐÍ
Ò»Ìå»ú£¨Ë«¿ØÖÆÆ÷¡¢ÄÚÖÃÇý¶¯Æ÷ÍмÜ¡¢ÁªÍøºÍÀ©Õ¹¶Ë¿Ú£© 

»ú¼Ü³ß´ç
3U

¿ØÖÆÆ÷
ÿ¸ö»úÏä2¸öÈȲå°Î¿ØÖÆÆ÷£¨Ö÷¶¯/Ö÷¶¯£© 

´¦ÀíÆ÷
Ó¢ÌØ¶û®ÖÁÇ¿® E5-2603v4´¦ÀíÆ÷£¬1.7 GHz£¬6¸öÄÚºË

ÄÚ²¿´æ´¢ÈÝÁ¿
SCv3000£º16¸ö3.5¡±Ó²ÅÌÍмÜ
SCv3020£º30¸ö2.5¡±Ó²ÅÌÍмÜ

ϵͳÄÚ´æ
ÿ¸öSCv3xxxÕóÁÐ32 GB£¨Ã¿¸ö¿ØÖÆÆ÷16 GB£©

²Ù×÷ϵͳ
Storage Center OS (SC OS) 7.2»ò¸ü¸ß°æ±¾

Êý¾ÝÒÆ¶¯ÐÔºÍÇ¨ÒÆ

¸´ÖÆ
ͨ¹ýÆäËûSCϵÁÐÕóÁÐ*½øÐи´ÖÆ
ͨ¹ýFC»òiSCSIͬ²½/Òì²½¸´ÖÆ
Ä¿±ê/Ô´¹ØÏµ¿ÉÒÔΪһ¶Ô¶à»ò¶à¶ÔÒ»
Ö§³ÖÔ´ºÍÄ¿±ê¾íÉϵÄËùÓÐSCÊý¾Ý·þÎñ
¿É°´Ðè¸ü¸Ä¸´ÖÆÀàÐͺÍÍØÆË
PSϵÁÐ/EqualLogicÕóÁÐÖ§³Ö¿çƽ̨¸´ÖÆ£¨ÈÎÒ»·½Ïò£©

¾íÒÆ¶¯ÐÔ
Live Migrate£¨»ù±¾²úÆ·ÖÐÅ䱸£©Ö§³ÖÕóÁмäÖ÷»ú͸Ã÷Êý¾ÝÒÆ¶¯£»ÁíÇë²ÎÔÄ¡°ÁªºÏ¡±²¿·Ö

ÁªºÏ¶àÕóÁÐϵͳ 
Live Migrate£¨»ù±¾²úÆ·ÖÐÅ䱸£©Ö§³ÖÕóÁмäÖ÷»ú͸Ã÷¾íÒÆ¶¯
ÔÚÇ¨ÒÆÆÚ¼ä±£³Ö/±£Áô¿ìÕÕ

Thin Import
´ÓPSϵÁÐ(EqualLogic)ÕóÁнøÐнÚÊ¡¿Õ¼ä¡¢ÎÞÖжϵÄÊý¾ÝÇ¨ÒÆ

Thin Clones
ÎÞÐè¸´ÖÆÊý¾Ý¼´¿É¿Ë¡¶ÀÁ¢µÄ¾í
ͨ¹ý¿Ë¡ά³Ö¶ÀÁ¢µÄ¿ìÕպ͸´ÖÆ
·Ç³£ÊʺÏVDI¡¢²âÊÔ/¿ª·¢¡¢ÆäËûÐèÒª¶ÀÁ¢µÄ³£¼ûÊý¾ÝʵÀýµÄÓ¦ÓóÌÐò
¶ÔÊý¾Ý¿â¸±±¾À´Ëµ£¬±ÈÖØ¸´Êý¾Ýɾ³ý¸ü¸ßЧ

Êý¾ÝÓÅ»¯

×Ô¶¯·Ö²ã·½·¨ 
¸ù¾ÝʵʱÊý¾ÝʹÓÃÇé¿ö½øÐлùÓÚ²ßÂÔµÄÇ¨ÒÆ£¬¿É×Ô¶¨ÒåµÄ512 KB-4 MBÒ³´óС¡£

×Ô¶¯·Ö²ã½á¹¹
×ܹ²×î¶à3¸öÖ÷£¨»ùÓÚ½éÖÊ£©²ã£¬×î¶à2¸öSSD²ã£¨¶ÁÈ¡ºÍдÈëÃܼ¯ÐÍSSD£©

·Ö²ã×Ô¶¨Òå
Óû§¶¨ÒåµÄÅäÖÃÎļþ£¬Èκβ㶼¿ÉÑ¡Ôñ¡°²åÕ롱¾í 

RAIDÖ§³Ö
RAID 0¡¢1¡¢5¡¢6¡¢RAID 10ºÍRAID 10 DM£¨Ë«¾µÏñ£©£»ÔÚµ¥Ò»ÕóÁÐÖпÉÈÎÒâ×éºÏʹÓø÷RAID¼¶±ð 

RAID·Ö²ã
¿ÉÔÚÏàͬ²ãÉÏ×Ô¶¯ÅäÖúͶ¯Ì¬·Ö¸ô¶à¸öRAID¼¶±ð£»ÎÞÐèÔ¤·ÖÅäRAID×é 

¾«¼òÅäÖÃ
ÔÚËùÓоíÉÏĬÈÏ´¦Óڻ״̬£¬¿ÉÈÃËùÓй¦ÄÜ´¦ÓÚ×î¸ßÐÔÄÜ 

¾«¼ò¿ìÕÕ
½ö¼Ç¼¸ü¸Ä£¬¿ìÕÕ×Ô¶¯Ç¨ÒÆÖÁµÍ³É±¾´æ´¢ 

ÖÇÄÜѹËõ
ÿ¸ö¾íÌṩ¿ÉѡѡÏî 
ÊÊÓÃÓÚSSD¡¢HDD»ò»ìºÏÅäÖÃ

HDDÓÅ»¯
FastTrack¿É½«×î³£·ÃÎʵÄÊý¾ÝÒÆ¶¯µ½Íâ²à´ÅµÀÉÏ£¬ÒÔ¼Ó¿ìÏìÓ¦ËÙ¶È

¹¤×÷»·¾³Ìõ¼þ

¹¤×÷ζÈ£º10 ¡ãC - 35 ¡ãC (50 ¡ãF - 95 ¡ãF)
·Ç¹¤×÷ζÈ£º-40 ¡ãC - 65 ¡ãC (-40 ¡ãF - 149 ¡ãF)
¹¤×÷ʪ¶È·¶Î§£¨ÎÞÀäÄý£©£º10 %µ½80 %£¬×î¸ß¶µãζÈΪ29 ¡ãC (84.2 ¡ãF)
·Ç¹¤×÷ʪ¶È£¨ÎÞÀäÄý£©£º5 %µ½95 %£¬×î¸ß¶µãζÈΪ33 ¡ãC (91 ¡ãF)
²å×ùÀàÐÍ£ºNEMA 5-15/CS22.2£¬n¡ã42


À©Õ¹ÈÝÁ¿

Ö§³ÖµÄÀ©Õ¹Å̹ñ
²âÊÔ
SCv300£º12¸ö3.5"Çý¶¯Æ÷ÍмÜ(12 Gb SAS)
SCv320£º24¸ö2.5"Çý¶¯Æ÷ÍмÜ(12 Gb SAS)
SCv360£º60¸ö3.5"Çý¶¯Æ÷ÍмÜ(12 Gb SAS)*

×î´óÓ²ÅÌÊýÁ¿
ÿ¸öÕóÁÐ222¸ö£¨ÄÚÖüÓÍⲿÀ©Õ¹£©£¬ÁªºÏϵͳÖÐÊýÁ¿¸ü¶à*

×î´óԭʼÈÝÁ¿ 
ÿ¸öÕóÁÐ1 PB*£¨¹Ì̬ӲÅÌ»òÓ²ÅÌ£©£¬ÁªºÏϵͳÖÐÈÝÁ¿¸ü´ó

×î´óԭʼÈÝÁ¿(NAS)
ÿ¸öÕóÁÐ1 PB*£¨ÐèÒªÅ䱸FS8600 NASÉ豸£©
µ¥Ò»ÃüÃû¿Õ¼ä4 PB£¨ÐèÒªÅ䱸FS8600ºÍ¶à¸öÕóÁУ© 
È«¾ÖÃüÃû¿Õ¼ä20 PB£¨ÐèÒªÅ䱸FS8600ºÍ¶à¸öÕóÁУ©
´ËÍ⣬»¹Ö§³ÖNX3000ϵÁÐWindows NASÉ豸

´æ´¢½éÖÊ
SASºÍNL-SASÓ²ÅÌ£»Í¬Ò»ÏµÍ³ÖпɻìºÏʹÓò»Í¬ÀàÐÍ¡¢´«ÊäËÙÂʺÍתËÙµÄÓ²ÅÌ¡£
¹Ì̬ӲÅÌ£ºÐ´Ãܼ¯ÐͺͶÁÃܼ¯ÐÍÓ²ÅÌ 
Ó²ÅÌ£º15K¡¢10K¡¢7.2K RPM

¹¦ÄÜ

ÕóÁÐÅäÖÃ
È«ÉÁ´æ¡¢»ìºÏ»òÓ²ÅÌÕóÁÐ

´æ´¢¸ñʽ
ͬһ³ØÖеĿé(SAN)ºÍ/»òÎļþ(NAS)*

×î´óSANÖ÷»úÊý£º250
×î´óÆô¶¯Æ÷¶Ë¿ÚÊý£º500
×î´óLUN´óС£º500 TB
×î´óLUNÊý£º1000
×î´ó¿ìÕÕÊý£º4096
×î´óIOPS£º665,000* 
×î´óIOPS£¨ÑÓ³Ùʱ¼äСÓÚ1ºÁÃ룩£º540,000* 
×î´óIOPS£¨80 %¶ÁÈ¡£¬20 %дÈ룩£º231,000* 
×î´óÍÌÍÂÁ¿£¨¶ÁÈ¡£©£º19,000 MB/s* 
×î´óÍÌÍÂÁ¿£¨Ð´È룩£º9,500 MB/s*

¹ÜÀí

¹ÜÀí½çÃæ
»ùÓÚä¯ÀÀÆ÷(HTML 5)£º 
Unisphere for SC£¨ÔªËعÜÀíÆ÷£©
Unisphere Central£¨¶àÕóÁйÜÀí£©
CloudIQ£¨»ùÓÚÔÆµÄ·ÖÎöºÍ¼à¿Ø£©

¿Í»§¶ËÓ¦ÓóÌÐò£º 
Dell Storage Manager£¨¶àÕóÁС¢¶àÕ¾µã¡¢¿çƽ̨¹ÜÀí£©

ÁªºÏ 
ÔÚͳһ¹ÜÀíÏ´´½¨´óÐͶàÕóÁÐϵͳ£¬Í¨¹ý¸½´øµÄLive Migrate¹¦ÄÜÔÚÕóÁÐÖ®¼ä½øÐÐÎ޷칤×÷¸ºÔØÇ¨ÒÆ¡£ÎÞÖжϵØÌí¼ÓÕóÁУ¬´Ó¶ø¸ßЧʹÓÃÆä×éºÏÈÝÁ¿ºÍÐÔÄÜ¡£Volume Advisor¿É¼à¿ØÁªºÏÕóÁУ¬ÒÔÌṩÀíÏëÊý¾Ý·ÅÖú͸ºÔØÆ½ºâ½¨Òé¡£¾íÒÆ¶¯²»»áÓ°Ïì¿ìÕÕ»ò¸´ÖÆÊý¾Ý±£»¤¡£*

½Å±¾Ö§³Ö
Microsoft PowerShell API
RESTful API

Ö÷»ú²Ù×÷ϵͳ֧³Ö
Microsoft® Windows Server®¡¢Novell® NetWare¡¢SLES¡¢VMware®¡¢Citrix® XenServer®¡¢RedHat®

µÚÈý·½Ó¦ÓóÌÐò¼¯³É
VMware¡¢Microsoft¡¢IBM¡¢OpenStack¡¢Oracle¡¢Symantec¡¢Commvault¡¢Foglight¡¢Docker

Êý¾Ý¾ÍµØÉý¼¶Ñ¡Ïî
½«Çý¶¯Æ÷´ÓSC4020Ö÷¿Øµ¥ÔªºÍ/»òÀ©Õ¹Å̹ñ×ªÒÆµ½ÐµÄSC5020/SC7020

ÓëPSϵÁÐÕóÁй²´æ
ÔÚÈÎÒ»·½Ïò½øÐи´ÖÆ 
ͨ¹ýµ¥¸ö½çÃæ¼´¿ÉÍê³ÉÈÕ³£¹ÜÀí
Thin Import£º´ÓPSϵÁÐÕóÁнøÐнÚÊ¡¿Õ¼ä¡¢ÎÞÖжϵÄÊý¾ÝÇ¨ÒÆ

ÈÏÖ¤
ͨ¹ýVMware vSphere Metro Storage Cluster¡¢VMware SRMºÍVeritas Storage Foundations SuiteÈÏÖ¤£»ÓÐ¹ØÆäËûÈÏÖ¤ºÍÏêϸÐÅÏ¢£¬Çë²Î¼û¡°Dell StorageÖ§³ÖÁÐ±í¡±

±¨¸æ/ÌáÐÑ
Support assist£¨µç»°/ÉÏÃÅ£©¡¢Ô¶³ÌÕï¶ÏºÍÐÔÄÜ¼à¿Ø¡¢×Ô¶¯ÌáÐÑ¡¢±¨¸æºÍ֪ͨ¡¢²¿ÃżƷÑ

¹¤×÷¸ºÔعÜÀí
QoS¡¢VVOL


ÍøÂçºÍÀ©Õ¹I/O

ǰ¶ËÍøÂçЭÒé
FC¡¢iSCSI¡¢SAS£¨Ö§³Öͬ²½¶àЭÒ飩£ºFC + iSCSI»òSAS + iSCSI

×î´ó16 Gb FC¶Ë¿ÚÊý
ÿ¸öÕóÁÐ8¸ö(SFP+)

×î´ó10 Gb iSCSI¶Ë¿ÚÊý 
ÿ¸öÕóÁÐ16¸ö£¨SFP+»òBaseT£©

×î´ó12 Gb SAS¶Ë¿ÚÊý
¶à´ï8¸ö12 Gb SAS¶Ë¿Ú* 

¹ÜÀí¶Ë¿Ú
ÿ¸öÕóÁÐ2¸ö(1 Gb BASE-T) 

ºó¶ËÀ©Õ¹Ð­Òé
12 Gb SAS 

×î´óºó¶ËÀ©Õ¹¶Ë¿ÚÊý
ÿ¸öÕóÁÐ8¸ö 
ÿ¸öÕóÁжà´ï16¸öÀ©Õ¹Å̹ñ

ÎïÀí

SCv3000
»ú¼Ü³ß´ç£º
3U
¸ß¶È£º13.33ÀåÃ×£¨5.25Ó¢´ç£©
¿í¶È£º 44.5ÀåÃ×£¨17.52Ó¢´ç£©
Éî¶È£º78.5ÀåÃ×£¨30.9Ó¢´ç£©
ÖØÁ¿£¨×î¸ßÅäÖã©£º24.22ǧ¿Ë£¨53.4°õ£©
ÖØÁ¿£¨¿Õ£©£º15.15ǧ¿Ë£¨33.4°õ£© 

SCv3020
»ú¼Ü³ß´ç£º3U
¸ß¶È£º13.33ÀåÃ×£¨5.25Ó¢´ç£©
¿í¶È£º44.5ÀåÃ×£¨17.52Ó¢´ç£©
Éî¶È£º78.5ÀåÃ×£¨30.9Ó¢´ç£©
ÖØÁ¿£¨×î¸ßÅäÖã©£º24.22ǧ¿Ë£¨53.4°õ£©
ÖØÁ¿£¨¿Õ£©£º15.15ǧ¿Ë£¨33.4°õ£©

µçÔ´Ñ¡Ïî*

¹¦ÂÊ/ÍßÊý£º2¸öÈȲå°ÎµçÔ´£¨1378 W»ò1485 WÑ¡Ï
×î´óÊä³ö¹¦ÂÊ£º1378 WµçÔ´Ñ¡Ï1378 W£»1485 WµçÔ´Ñ¡Ï1485 W 
×î´óÊäÈ빦ÂÊ£º1378 WµçÔ´Ñ¡Ï1584 W£»1485 WµçÔ´Ñ¡Ï1688 W 
×î´óÊäÈëµçÁ÷£º1378 WµçÔ´Ñ¡Ï16 A£»1485 WµçÔ´Ñ¡Ï8.8 A 
×î´óµçÓ¿µçÁ÷£º55 A£¬³ÖÐø10ºÁÃë»ò¸ü¶Ìʱ¼ä 
¶î¶¨ÊäÈëµçѹ¹¤×÷·¶Î§£º1378 WµçÔ´Ñ¡Ï100-240 VAC£»1485 WµçÔ´Ñ¡Ï200-240 VAC 
¶î¶¨ÊäÈëÆµÂÊ£º50/60 Hz
×î´óÈÈÁ¿Êä³ö/É¢ÈÈ£º1378 WÑ¡ÏÿСʱ5,770 BTU£»1485 WÑ¡ÏÿСʱ5,760 BTU£¨ÊÊÓÃÓÚÎÞÀ©Õ¹Å̹ñµÄÒ»Ìåʽ»ù´¡É豸£©

Êý¾Ý±£»¤¹¦ÄÜ

ÒµÎñÁ¬ÐøÐÔ 
Live VolumeË«Ïò×Ô¶¯¹ÊÕÏ×ªÒÆ¡¢×Ô¶¯ÐÞ¸´*
³ÖÐøÔËÐС¢ÔÖÄѻָ´¡¢ÔÖÄѱÜÃâ 
°üÀ¨Èý¼¶Õ¾µã£¨Èý¼¶£©¸´ÖÆÑ¡ÏîÒÔ¼°Live VolumeÍйܸ´ÖÆ*
ÁãRTO/RPO£¬Ã¿¸ö¾í¾ßÓпÉ×Ô¶¨ÒåµÄÕ¾µã¹ÊÕÏ×ªÒÆSLA 
VMware Metro Stretch ClusterÖ§³Ö 
VMware Site Recovery Manager 

·Ö²¼Ê½±¸·Ý
ÎÞÐèרÓÃÈȱ¸ÅÌ£¬ËùÓÐÇý¶¯Æ÷¾ù¿ÉÓÃÓÚI/O

¾«¼ò¿ìÕÕ 
½ö¼Ç¼¸ü¸Ä£¬¿ìÕÕ×Ô¶¯Ç¨ÒÆÖÁµÍ³É±¾´æ´¢

Ó¦ÓóÌÐòÒ»ÖÂÐÔ
Replay Manager£ºMicrosoft»òVMware»·¾³ÖеÄÓ¦ÓóÌÐòÒ»ÖÂÐÔ¿ìÕÕ
AppSync£ºÔÚMicrosoft¡¢VMwareºÍOracle»·¾³ÖÐÌṩӦÓóÌÐòÒ»ÖÂÐÔ¿ìÕÕ

¾²Ì¬Êý¾Ý¼ÓÃÜ
¹Ì̬ӲÅÌ»òÓ²Å̸ñʽµÄ×Ô¼ÓÃÜÇý¶¯Æ÷(SED) 
»ùÓÚAES-256µÄÈ«´ÅÅ̼ÓÃÜ(FCE)
Ó²Å̾­¹ýFIPS 140-2µÚ2¼¶ÈÏÖ¤ 
ÊÊÓÃÓÚFIPS 140-2µÚ1¡¢2ºÍ3¼¶µÄÃÜÔ¿¹ÜÀí·þÎñÆ÷(KMS)Ñ¡Ïî

External Key ManagerÖ§³Ö
Gemalto SafeNet KeySecure k460¡¢SafeNet KeySecure k250¡¢SafeNet KeySecure k150v
Thales EMS 200


²úÆ·ÌØÕ÷

ÔÚÈκÎÅäÖã¨È«ÉÁ´æ¡¢»ìºÏ´æ´¢ºÍÓ²ÅÌ£©ÖУ¬SCϵÁÐÕóÁж¼·Ç³£¸ßЧ£¬µ«ÎÒÃÇÖªµÀÐí¶àÆóÒµÔÚ²¿ÊðÈ«ÉÁ´æÕóÁÐʱ¶¼Ìرð¹Ø×¢¿ªÖ§¡£Îª´Ë£¬ÎÒÃÇΪËùÓÐÈ«ÉÁ´æSCÅäÖÃÌṩÓб£Ö¤µÄ4:1ЧÂÊ£¬Ïû³ýAFAËù´øÀ´µÄ·çÏÕ¡£Dell EMC³Ðŵ£¬¶ÔÓÚÄúËù¹ºÂòµÄÇý¶¯Æ÷µÄÎïÀíÈÝÁ¿£¬ÎÒÃǵÄÈ«ÉÁ´æÕóÁн«ÌṩÖÁÉÙËı¶µÄÓÐЧÂß¼­´æ´¢ÈÝÁ¿ ¨C ·ñÔò£¬ÎÒÃǽ«Ãâ·ÑΪÄúÌṩ¸ü¶àÇý¶¯Æ÷¡£*



¡¾±¾ÎıêÇ©¡¿£º
·¢²¼Ê±¼ä£º2018-11-22 0:00:00
À´Ô´£ºhttp://www.hotdetoxllc.com/supply/74.html